In the event of a fire, a smoke control system is used to keep a building's escape routes and access routes free from smoke, assist fire-fighting operations and delay or prevent flashover, thereby reducing the risk that the fire will escalate.[1]
In the United Kingdom, the Smoke Control Association operates as a professional and advisory organisation in this field.[2]
Standards
Within the International Organization for Standardization (ISO), Technical Committee ISO/TC 21/SC 11 is responsible for the development of standards concerned with smoke and heat control systems and components.[3]
In Australia and New Zealand, joint standard AS/NZS 1668.1:2015 aims to provide:
standardized minimum requirements for mechanical air-handling and mechanical smoke control systems for use by designers, installers, inspectors and regulators of these systems.[4]
Requirements for the maintenance of smoke control systems fall outside this standard.[4]
References
- ^ Smoke Control Association, FAQs: Your Questions Answered, accessed 20 September 2021
- ^ Smoke Control Association, accessed 20 September 2021
- ^ ISO, ISO/TC 21/SC 11: Smoke and heat control systems and components, accessed 6 October 2021
- ^ a b Victorian Building Authority, Australian/New Zealand Standard: The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings. Updated AS/NZS 1668.1:2015, published March 2016, accessed 6 October 2021
- v
- t
- e
- Backdraft
- Boiling liquid expanding vapor explosion (BLEVE)
- Boilover
- Combustibility and flammability
- Conflagration
- Dangerous goods (HAZMAT)
- Deflagration
- Detonation
- Dust explosion
- Enthalpy of vaporization
- Explosive
- Fire class
- Fire control
- Fire loading
- Fire point
- Fire triangle
- Flammability diagram
- Flammability limit
- Flammable liquid
- Flashover
- Flash point
- Friction loss
- Gas leak
- Heat transfer
- Jet fire
- K-factor (fire protection)
- Pool fire
- Pyrolysis
- Spontaneous combustion
- Structure fire
- Thermal radiation
- Water pressure
- Active fire protection
- Automatic fire suppression
- Condensed aerosol fire suppression
- Detonation flame arrester
- External water spray system
- Fire bucket
- Fire prevention
- Fire protection
- Fire retardant
- Fire-retardant fabric
- Fire retardant gel
- Fire-safe polymers
- Fire safety
- Fire sprinkler system
- Fire suppression system
- Firefighting foam
- Flame arrester
- Flame retardant
- Flashback arrestor
- Fusible link
- Gaseous fire suppression
- Hypoxic air technology for fire prevention
- Inerting system
- Intumescent
- Passive fire protection
- Personal protective equipment (PPE)
- Relief valve
- Spark arrestor
- Tank blanketing
- Vehicle fire suppression system
- Annulus (firestop)
- Area of refuge
- Booster pump
- Compartmentalization (fire protection)
- Crash bar
- Electromagnetic door holder
- Electromagnetic lock
- Emergency exit
- Emergency light
- Exit sign
- Fire curtain
- Fire cut
- Fire damper
- Fire door
- Fire escape
- Fire extinguisher
- Fire hose
- Fire hydrant
- Fire pump
- Fire sprinkler
- Firestop
- Firestop pillow
- Firewall (construction)
- Grease duct
- Heat and smoke vent
- Occupancy
- Packing (firestopping)
- Penetrant (mechanical, electrical, or structural)
- Penetration (firestop)
- Pressurisation ductwork
- Safety glass
- Smoke control
- Smoke damper
- Smoke exhaust ductwork
- Smokeproof enclosure
- Standpipe (firefighting)
and services
- Template:Fire
- Template:Firefighting
- Template:HVAC
- Category
- Commons
This article relating to firefighting is a stub. You can help Wikipedia by expanding it. |
- v
- t
- e